11kv 22kv 33kv Dry Type Epoxy Resin Distribution Transformer

Product Details
Customization: Available
Application: Power
Core: Amorphous Alloy Transformer
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (27)
Find Similar Products

Basic Info.

Model NO.
SC(B)9/SC(B)10/SC(B)11
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, CCC
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Westhomes
Capacity
30-2500kVA
Voltage
11kv, 22kv, 33kv
Transport Package
Wooden Case
Specification
IEC60076
Trademark
Westhomes
Origin
Prc
HS Code
8504220000
Production Capacity
50000

Product Description

10/20//35kV Epoxy Resin Dry-type transformer

Application: for power distribution system and large industrial enterprises etc.
Standards: IEC60076-11
Rated voltage: 11/33kV                      
capacity range: 30kVA-2500kVA

Feature:
High security and reliability in operation                
Economic and efficient to reduce network loss and operation cost.                
Low temperature rise.                
Operation in moist place with high moisture-proof capability.                
Customized transformers are available on your requirement.

Technical parameters of SC9, SCR9, SCB9 series resin cast insulated dry-type power transformers
 
Rated capacity kVA voltage combination Low voltage kV Connection symbol No-load loss W Load loss W 120ºC No-load current % Short circuit resistance % Insulation class Track gauge mm Noise level dB Weight kg
High voltage kV High voltage tapping range
30 6     
6.3 
6.6   
10         
10.5     
11
35
38.5
±2×2.5% or ±5% or other 0.4      3.15        6          6.3        10       10.5      11 Yyn0         or Dyn11   Yd11 220 750 750 4 F/F 500×500 42 315
50 310 1060 1060 42 360
80 420 1460 1460 42 415
100 450 1660 1660 42 580
125 530 1950 1950 44 785
160 610 2250 2250 44 820
200 700 2670 2670 45 970
250 810 3910 3910 660×660 45 1090
315 990 3670 3670 820×820 46 1250
400 1100 4220 4220 47 1590
500 1310 5170 5170 47 1740
630 1510 6220 6220 820×820 49 2110
630 1460 6310 6310 6 49 2020
800 1710 7360 7360 1070×1070 50 2300
1000 1990 8600 8600 50 2830
1250 2350 10260 10260 52 3350
1600 1750 12420 12420 52 3970
2000 3400 15300 15300 54 4800
2500 4000 18180 18180 54 5400
800 2500 9900 9900 820×820 50 3360
1000 2970 11500 11500 50 4090
1250 3480 13600 13600 1070×1070 51 4330
1600 4100 16300 16300 51 5800
2000 4700 19200 19200 7 52 6590
2500 5400 23000 23000 53 7550
3150 6700 25800 25800 8 1475×1475 57 8900
4000 7800 31000 31000 57 9520
5000 9360 36800 36800 57 12840
6300 11000 43000 43000 59 13860
8000 12600 48500 48500 9 59 16100
10000 14400 58500 58500 61 21180
12500 17500 68000 68000 61 25600
16000 21500 80000 80000 61 35700

Technical parameters of SCR10, SC10, SCB10 series resin cast insulated dry-type power transformers
 
Rated capacity kVA voltage combination Low voltage kV Connection symbol No-load loss W Load loss W 120ºC No-load current % Short circuit resistance % Insulation class Track gauge mm Noise level dB
High voltage kV High voltage tapping range
30 6                      6.3                  6.6                  10                10.5                  11                    ±2×2.5% or ±5% or other 0.4 Yyn0         or Dyn11    190 710 1.0  4 F/F 500×500 40
50 270 1000 1.0  500×500 40
80 360 1380 0.9  500×500 40
100 400 1570 0.8  500×500 41
125 470 1850 0.75  500×500 41
160 540 2130 0.75  500×500 43
200 620 2530 0.7  500×500 43
250 720 2760 0.7  500×500 44
315 880 3470 0.6  660×660 44
400 980 3990 0.6  820×820 45
500 1160 4880 0.6  820×820 45
630 1340 5880 0.5  820×820 46
630 1300 5960 0.5  6 820×820 47
800 1520 6960 0.5  820×820 47
1000 1770 8130 0.4  820×820 48
1250 2090 9690 0.4  1070×1070 48
1600 2450 11730 0.4  1070×1070 49
2000 3050 14450 0.3  1070×1070 50
2500 3600 17170 0.3  1070×1070 50

Overall and installation dimensions of 10kV SCR9, SC9, SCB9 series

Overall and installation dimensions of 10kv SCR9, SC9, SCB9



Overall dimensions of 10kv SCR9, SC9, SCB9 series with shell



Technical parameters of 10kv SCRZ9, SCZ9, SCBZ9 series resin insulated on-load-tap-changing dry-type power transformers
 
Rated capacity kVA voltage combination no-load loss W load loss W  No-load current % Short circuit resistance % Insulation class Track gauge mm Noise level dB
High voltage kV High voltage tapping range Low voltage kV Connection symbol
315 6              6.3          6.6           10          10.5         11 ±4×2.5% 0.4 Yyn0 or Dyn11 or other 990 3825 0.8 4 H or F 660×660 45
400 1100 4490 0.8 820×820 46
500 1300 5450 0.8 46
630 1510 6500 0.8 47
630 1460 6630 0.6 6 47
800 1710 7840 0.6 48
1000 1990 9270 0.5 48
1250 2350 11160 0.5 1070×1070 49
1600 2750 12420 0.5 49
2000 3740 16100 0.4 50
2500 4500 19170 0.4 50

Overall dimension of 10kV SCRZ9, SCBZ9 series


Technical parameters of 20kV SCR10 series off-circuit-tap-changing dry-type distribution transformers
 
Rated capacity kVA voltage combination no-load loss W load loss W  No-load current % Short circuit resistance % Noise level dB Track gauge mm
High voltage kV High voltage tapping range Low voltage kV Connection symbol
50 20            22                     24 ±5% or ±2×2.5% 0.4 Yyn0         or Dyn11    340 1235 2.4 4 42 500×500
100 540 1890 1.2 42 500×500
160 675 2470 1.8 43 500×500
200 740 2945 1.8 44 500×500
250 850 3420 1.6 44 500×500
315 970 4085 1.6 46 660×660
400 1150 4845 1.4 46 820×820
500 1350 5795 1.4 47 820×820
630 1530 6840 1.2 6 47 820×820
800 1755 8265 1.2 48 820×820
1000 2070 9785 1.0  48 820×820
1250 2385 11540 1.0  49 1070×1070
1600 2790 13870 1.0  50 1070×1070
2000 3240 16380 0.8 8 51 1070×1070
2500 3870 19380 0.8 52 1070×1070


Technical parameters of 35kV SCRZ9, SCZ9, SCBZ9 series resin insulated on-load-tap-changing dry-type power transformers
 
Rated capacity kVA voltage combination no-load loss W load loss W  No-load current % Short circuit resistance % Insulation class Track gauge mm Noise level dB
High voltage kV High voltage tapping range Low voltage kV Connection symbol
315 35   
38.5
±2×2.5% or ±5% or other 0.4 Yyn0 or Dyn11 1170 4510 0.2 6 F 820×820 47
400 1380 5420 0.2 820×820 47
500 1620 6650 0.2 820×820 48
630 1860 7300 1.8 820×820 48
800 2160 9120 1.8 820×820 49
1000 2430 10450 1.8 820×820 50
1250 2840 12730 1.6 1070×1070 50
1600 3240 15490 1.6 1070×1070 51
2000 3830 18240 1.4 1070×1070 53
2500 4460 21850 1.4 1070×1070 54


Frequently Asked Question (FAQ)
Q:  About the company
A: Westhomes® is a professional manufacturer for low voltage and high voltage electrical products with a thirty-year history.
    Main supplier of state-owned companies like China Stae Grid, China Southern Power Grid through bidding with bunches of test certificates, sales records and operation performance to support.
    Enough investment for research and development for the products innovation.

Q:  About Warranty
 A: 18 months from the date of receivement

Q: About shipment method
A: Depends on the required quantity and delivery urgency, both international express like UPS / DHL / EMS / HK EMS / FedEx / TNT (door to door service) and normal sea shipping & air freight also avaliable.

Q: About MOQ
A: Upto the client

Q: About payment method
A: We accept T/T, Paypal, Western union, L/C. Normally 30% payment in advance, 70% before delivery.

Q:About ordering process
A: First to send an inquiry via made-in-china platform or directly to the contact e-mail address. All the following thing is the communication between us.


Contact
Ms Stephanie Huang
Senior Sales Manager
Add: Liushi Town, Yueqing City, Zhejiang Provine, China 325604
http://westhomes.en.made-in-china.com/ 
Mob: 0086-13868328363
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier